Private on-device repair evidence
Nozzle Scraping or Hitting the Print
A detailed STLBEAST repair guide to separate harmless travel sounds from real collision risk. Learn how to recognize the symptom, rank the likely causes, apply safe fixes in order, verify the result, and prevent the failure from returning.
Not started0 of 8 stepsNot yet saved

Record the setup that produced this result
Saved only in this browser with the repair. Nothing is uploaded.
Add before and after photos for this report
Photos stay in this open page only and are never stored or uploaded. They appear in the printed report while the page remains open.
Controlled test history
No controlled tests have been logged yet. Return to Workshop Mode and record each change before running another test.
Step completion
- 1Document the failure and confirm that it matches this guide: The nozzle drags across infill, knocks the model, or leaves scratches on top surfaces.Not completed
- 2Return extreme overrides to a known printer, nozzle, material, and slicer profile so the diagnosis starts from a stable baseline.Not completed
- 3Check over-extrusion. Check for raised plastic.Not completed
- 4Check warping or curled edges. Verify hotend and gantry tightness.Not completed
- 5Inspect loose hotend or gantry. Reduce excess flow.Not completed
- 6Rule out travel strategy or missing z-hop. Use Z-hop only when needed.Not completed
- 7Change only the single setting or hardware condition supported by the evidence, then run a small test that reproduces the original failure.Not completed
- 8Compare the test against the target condition, record the successful value, and save it in a printer/material profile before repeating the full print.Not completed
Observations and winning values
No notes recorded.
Verification test
- Model
- 100 mm extrusion and thin-wall test
- Setup
- Use the same nozzle, material and hotend temperature planned for the print.
- Pass
- Flow is smooth and the wall is continuous with stable width.
- If unchanged
- Clicking, gaps, pulsing or inconsistent line width remains.