Private on-device repair evidence
Nozzle Too Far from the Bed
Fix round, loose first-layer lines, gaps, weak adhesion, and lines that follow the nozzle.
Not started0 of 5 stepsNot yet saved

Record the setup that produced this result
Saved only in this browser with the repair. Nothing is uploaded.
Add before and after photos for this report
Photos stay in this open page only and are never stored or uploaded. They appear in the printed report while the page remains open.
Controlled test history
No controlled tests have been logged yet. Return to Workshop Mode and record each change before running another test.
Step completion
- 1Clean the surface before changing Z offset.Not completed
- 2Run a bed mesh or leveling routine with the plate installed correctly.Not completed
- 3Lower Z offset in very small increments during a first-layer test.Not completed
- 4If line width remains inconsistent, inspect flow and nozzle condition.Not completed
- 5Check probe mount, hotend, wheels/rails, and build-plate seating.Not completed
Observations and winning values
No notes recorded.
Verification test
- Model
- Single-layer five-zone test
- Setup
- Use the final plate, material, mesh and first-layer profile.
- Pass
- Lines join evenly in the centre and corners, with no scraping, gaps or lifting.
- If unchanged
- One or more zones remain loose, transparent, ridged or detached.